3-8 SPARC Enterprise M3000 Server Installation Guide • January 2009
3. Check the LEDs of the XSCF unit.
FIGURE 3-4 shows the locations of the LEDs on the rear panel of the XSCF unit.
The CHECK LED (1) of the XSCF unit is turned on almost immediately after the
AC power supply system is turned on. The READY LED (2) of the XSCF unit
flashes during XSCF initialization and stays on when the initialization has been
completed.
FIGURE 3-4 LEDs on the XSCF Unit
4. Watch the administration console for error messages as the XSCF Unit powers
on.
For details on troubleshooting during installation work, refer to Appendix B.
5. Confirm that the XSCF STANDBY LED (green) on the operator panel is lit.
6. When the login prompt appears, type default as the login name
7. When a message prompting a mode switch operation appears, set the mode
switch on the operator panel as described below.
a. Set the mode switch on the operator panel to Locked, and press the RETURN
key.
Location number LED name
1 CHECK LED
2 READY LED
login: default
Change the panel mode switch to Locked and press return...
2
1