Chapter 3 Installing the Server 3-5
Note It is possible to connect it to a LAN port via telnet or SSH access. The LAN
port has a Class B private address value, but it will not send out a packet by itself
until configured.
Note The modular connector (RCI connector) is not for use with a TNV circuit
connection. See Item 1 in FIGURE 3-2.
1. Confirm that the following settings have been made for software on the
administration console.
2. Prepare the serial cable.
The serial cable is supplied with the server.
3. Connect the serial port on the rear panel to the administration console.
FIGURE 3-2 shows the locations of the external interface port such as serial port
and LAN ports on the rear panel.
TABLE 3-1 Terminal Software Setting Values
Setting item Value
Baud rate 9600
Data length 8 bits
Parity None
STOP bit 1 bit
Flow control None
Delay Other than 0