Dil ID: 12
Dil Adı: portugal
Dil Kodu: pt6tayfun Produtos da Marca Dell
Dünyanın En Büyük
Elektronik Bilgi Kütüphanesi



Alert! Previous
temperature failure
at Processor 1.
Secondary processor exceeded its recommended
operating temperature range during the previous
operating session.
Ensure an operational processor fan is installed,
connected to the system board, and that chassis
ventilation slots are not blocked.
Alert! Previous
voltage failure.
System voltage exceeded or fell below acceptable
thresholds.
See "Troubleshooting the System Board."
Alert! Processor 0
failed Build-
In Self
Test(BIST).
Primary processor is faulty or improperly seated.
Reseat the processor, or replace a faulty processor.
Alert! Processor 1
failed Build-
In Self
Test(BIST).
Secondary processor is faulty or improperly seated.
Reseat the processor, or replace a faulty processor.
Alert! Processor
Cache Size Mismatch.
Two processors with different L2 cache sizes are
installed.
Replace one of the processors so that the L2 cache
sizes match, or install a termination card in PROC_1
slot on system board.
Alert! Processor
Speed Mismatch.
Install like
processors or one
processor and a
termination card.
Two processors that are not of the same speed are
installed.
Replace one of the processors so that the speeds
match, or install a termination card in PROC_1 slot on
system board.
Alert! Processor
Type Mismatch.
Install like
processors or one
processor and a
termination card.
Two processors that are not of the same type are
installed.
Replace one of the processors so that the types match,
or install a termination card in PROC_1 slot on system
board.
Alert! Single-bit
memory error
previously detected
in XXXXh.
Faulty or improperly seated RIMMs or defective system
board.
See "Troubleshooting System Memory" and
"Troubleshooting the System Board."
Alert! System
battery voltage is
low.
System battery is providing inadequate voltage.
See "Troubleshooting the Battery."
Alert! System fan
not detected.
No system fan is installed; system fan has failed;
system fan is not connected to the system board.
Ensure an operational system fan is installed and
connected to the system board.
Alert! Uncorrectable
memory error
previously detected
in XXXXh.
Faulty or improperly seated RIMMs or defective system
board.
See "Troubleshooting System Memory" and
"Troubleshooting the System Board."
Attachment failed to
respond
The diskette drive or hard-disk drive controller cannot
send data to the associated drive.
See "Troubleshooting Drives."
Bad command or file
name
The command you entered does not exist or is not in
the pathname you specified.
Make sure you have spelled the command correctly,
placed spaces in the proper location, and used the
correct pathname.
Bad error-
correction
code(ECC) on disk
read
The diskette drive or hard-disk drive controller detected
an uncorrectable read error.
See "Troubleshooting Drives."
Controller has
failed
The hard-disk drive or the associated controller is
defective.
See "Troubleshooting Drives."
Data error
The diskette or hard-disk drive cannot read the data.
Run the ScanDisk utility in Microsoft
®
Windows
®
to
check the file structure of the diskette or hard-disk
drive. See your operating system documentation for
more information.
If you are using another operating system, run the
appropriate utility to check the file structure of the
diskette or hard-disk drive. See your operating system
documentation.
Decreasing available
memory
One or more RIMMs may be faulty or improperly
seated.
See "Troubleshooting System Memory."
Diskette drive 0
seek failure
Diskette drive 1
seek failure
A cable may be loose, or the system configuration
information may not match the hardware configuration.
See "Troubleshooting Drives."
Diskette read
A cable may be loose, or the diskette may be faulty.
See "Troubleshooting Drives."