Your application programs, operating system, and the computer itself are capable of identifying problems and alerting you to them. When a
problem occurs, a message may appear on your monitor screen or a beep code may sound. See "System Messages" or "System Beep Codes"
for information about each message or beep code.
System Messages
If you receive a system message, see Table 1 for suggestions on resolving any problems indicated by the message. The system messages are
listed alphabetically.
Table 1. System Messages
Overview
Diagnostics Messages
System Messages
Diagnostic LEDs
System Beep Codes
SNMP Platform Event Traps
Warning Messages
NOTE: If the system message you received is not listed in the table, check the documentation for the application program that you were
running at the time the message appeared and/or the operating system documentation for an explanation of the message and a
recommended action.
Message
Cause
Action
Address mark not
found
The BIOS found a faulty disk sector or could not find a
particular disk sector.
See "Troubleshooting Drives."
Alert! Card-
cage fan
not detected.
Expansion card cage fan not installed in mini tower
chassis; expansion card cage fan has failed; expansion
card cage fan is not connected to the system board.
Ensure that an operational expansion card cage fan is
installed and connected to the system board.
Alert! Cover was
previously removed.
The computer cover was removed.
Reset Chassis Intrusion in System Setup.
Alert! Hard drive
thermal probe not
detected.
No hard-disk drive thermal probe is installed; system
has a defective thermal probe; thermal probe cable is
not connected to the control panel.
Ensure that an operational hard-disk drive thermal
probe is installed and connected to the control panel.
Alert! Power supply
fan failure.
Power supply fan has failed or is blocked.
Ensure an operational power supply fan is installed and
that chassis ventilation slots are not blocked.
Alert! Previous
card-cage fan
failure.
Expansion card cage fan has failed or is blocked.
Ensure an operational expansion card cage fan is
installed, connected to the system board, and that
chassis ventilation slots are not blocked.
Alert! Previous hard
drive temperature
failure.
Hard-disk drive(s) exceeded recommended operating
temperature range during the previous operating
session.
Ensure fans are operational and that chassis ventilation
slots are not blocked.
Alert! Previous
power supply fan
failure.
Power supply fan failed or was blocked during the
previous operating session.
Ensure an operational power supply fan is installed and
that chassis ventilation slots are not blocked.
Alert! Previous
shutdown due to
thermal event.
Microprocessor(s) or hard-disk drive(s) exceeded
recommended operating temperature range during the
previous operating session. System was shut down to
protect the components.
Ensure fans are operational and that chassis ventilation
slots are not blocked.
Alert! Previous
system fan failure.
System fan failed or was blocked during the previous
operating session.
Ensure an operational system fan is installed,
connected to the system board, and that chassis
ventilation slots are not blocked.
Alert! Previous
temperature failure
at Processor 0.
Primary processor exceeded its recommended
operating temperature range during the previous
operating session.
Ensure an operational processor fan is installed,
connected to the system board, and that chassis
ventilation slots are not blocked.