INSTALLATION INSTRUCTIONS
STRAIN RELIEF
CONNECTOR
KNOCK-OUT
(TWIST TO REMOVE)
SUPPLY WIRE
GROUNDING
SCREW
1. WARNING
Verify that the electrical supply wires are the same
voltage as the heater.
2. If replacing an existing heater, check the label
of the old heater.
3. All electrical work and materials must comply
with the National Electric Code (NEC), the Occu-
pational Safety and Health Act (OSHA), and all
state and local codes.
4. If you need to install a new circuit or need addi-
tional wiring information, consult a qualied elec-
trician.
5. Use copper conductors only.
6. WARNING
Risk of Electrical Shock. DO NOT install the heat-
er directly above bathtub or sink. DO NOT install
in shower stall area (Manufacturer recommends a
minimum 2 foot clearance).
7. Heater must be installed in a wall can:
Model CB Wall Can CC
8. WARNING
Risk of Fire. DO NOT install the heater in a oor,
in the ceiling, below a towel bar, behind a door,
or anywhere the air discharge may be blocked in
any manner.
9. WARNING
Fire or Explosion May Occur. A heater has hot
and arcing or sparking parts inside. Do not use it
in areas where gasoline, paint, or ammable va-
pors or liquids are used or stored.
10. WARNING
Risk of Electrical Shock. Connect grounding lead
to grounding screw provided. Keep all foreign ob-
jects out of heater.
11. WARNING
Risk of Fire. This heater is hot when in use.
Caution—High Temperature. Risk of Fire. Keep
electrical cords, drapery, furnishings, and other
combustibles at least 3 feet from the front of the
heater and 6 inches above and on both sides.
__________________________
Part One
__________________________
PLACEMENT: Install the Com-Pak Bathroom Heater (Model CB) vertically. Heater is not approved for horizontal or ceiling mount appli-
cations.
THERMOSTAT: A built-in thermostat and 60 minute timer. (Note: Cannot be used with a wall thermostat.)
REQUIRED MINIMUM distance of 6 inches from adjacent
surfaces and 4½ inches from the oor (See Figure 4). However,
Cadet recommends 12 inches from adjacent surfaces and oor
for longer and cleaner performance. Heaters must be spaced at
least 3 feet apart.
Secure the wall can to the stud with 2 screws (not included)
through holes provided in the wall can. As an option, the rubber
shim provided may be attached to the side of the wall can to
square the wall can to the stud (See Figures 1 and 2).
How do I install for new construction?
STEP 1
Mount The Wall Can
Figure 1
Figure 2
Face of wall
can must
extend ½
inch or ⅝
inch from
face of stud
to allow for
thickness of
sheetrock.
Attach wall can to stud with
screws (not included), through
holes provided in wall can.
STEP 2
Route Supply Wires
Route supply wire from the GFCI circuit breaker to the wall can.
Remove a knockout from the wall can and attach the supply wire
with a strain relief connector (not included) leaving a minimum
of 6 inches wire lead. Connect supply ground wire to grounding
screw in wall can (See Figure 3).
Proceed to Part Two.
How do I install in an existing wall?
STEP 1
Cut A Hole In The Wall
REQUIRED MINIMUM distance of 6 inches from adjacent
surfaces and 4½ inches from the oor (See Figure 4). However,
Cadet recommends 12 inches from adjacent surfaces and oor for
longer and cleaner performance. Heaters must be spaced at least
3 feet apart.
Cut a hole 8 inches wide by 10¼ inches high next to a wall stud.
STEP 2
STEP 3
Route Supply Wires
Mount The Wall Can
Insert wall can into opening; keeping front of the wall can ush
with the nished wall surface. Secure the wall can to the stud with
2 screws (not included) through holes provided in the wall can. As
an option, the rubber shim provided may be attached to the side
of the wall can to square the wall can to the stud (See Figures 1
and 2).
Proceed to Part Two.
Route supply wire from the GFCI circuit
breaker to the wall can. Remove a
knockout from the wall can and attach
the supply wire with a strain relief con-
nector (not included) leaving a minimum
of 6 inches wire lead. Connect supply
ground wire to grounding screw in wall
can (See Figure 3).