Dil ID: 1
Dil Adı: english
Dil Kodu: en7tayfun Microcom Brand's Products
Dünyanın En Büyük
Elektronik Bilgi Kütüphanesi



203203203203203
13-20 438 Operator’s Manual - 880052-0100
^A ^D COMMAND
X 155 Set Feed Speed: Sets the feed speed used with the D153 and D154
commands.
0 8.0 ips (inches per second)
1 7.5 ips
2 7.0 ips
3 6.5 ips
4 6.0 ips
5 5.5 ips
6 5.0 ips
7 4.5 ips
8 4.0 ips
9 3.5 ips
10 3.0 ips
11 2.5 ips
12 2.0 ips
13 1.5 ips
14 1.0 ips
X 156 Set Non-stick Time Interval: Sets the time interval for the Non-stick TOF
mode (D26 position 8). The value for X represents the number of seconds
that the printer will execute the Non-stick TOF operation. The default setting is
14400 or 4 hours. The valid range is from 2 to 65536.
X 157 Takeup Motor Run Time: Only used with custom Takeup PIC code. The
value for X represents how long the takeup motor will run, in milliseconds,
after printing has stopped.
0 0
1 25 25 msec
2 50
3 75
4 100
5 125
6 150
7 175
8 200
9 225
10 250
11 275
12 300
13 325
14 350
15 375
16 400
17 425
18 450
19 475
20 500
21 525
22 550