Dil ID: 8
Dil Adı: italy
Dil Kodu: it6tayfun Prodotti del Marchio HP
Dünyanın En Büyük
Elektronik Bilgi Kütüphanesi



ProLiant BL p-Class
ProLiant BL p-ClassProLiant BL p-Class
ProLiant BL p-Class
Power System and
Power System andPower System and
Power System and
Rack Information
Rack InformationRack Information
Rack Information
NOTE:
NOTE:NOTE:
NOTE:
To determine power configuration, please refer to the ProLiant BL p-Class Overview and Planning Whitepaper and
sizing utility at
http://www.hp.com/products/servers/proliant-bl/p-class/info/
.
ProLiant BL p-Class
ProLiant BL p-ClassProLiant BL p-Class
ProLiant BL p-Class
Power Enclosure
Power EnclosurePower Enclosure
Power Enclosure
3U (5.25-inch), 19-inch wide, 29-inch deep (0.48-metre wide, 0.74-metre deep), dual input single phase and three phase
models available.
BL p-Class power enclosure provides scalable rack-centralized, hot-plug power without the need for PDUs.
Each 3 phase power enclosure houses six hot-plug power supplies
Each single-phase power enclosure holds four hot-plug power supplies
Please use the sizing utility to determine the power needed for each configuration
http://h30099.www3.hp.com/configurator/powercalcs.asp
NOTE:
NOTE:NOTE:
NOTE:
3 phase power enclosure options highly recommended for BL30p deployments.
Power enclosures and power supplies are not needed if using facility DC (-48V DC ± 10%). If using facility DC, Facility DC
Power Connection kit (240563-B21) is needed.
BL p-Class Power
BL p-Class PowerBL p-Class Power
BL p-Class Power
Distribution
DistributionDistribution
Distribution
-48 VDC power (from the power enclosures or facility DC power) is carried from the power enclosures to the server blade
enclosures through bus bars (for multiple enclosures) or power bus boxes (for a single enclosure). Hinges attach the bus bars
to the rack rails and provide easy rear access to the blade enclosures and interconnects. Power is distributed through
independent A- and B-sided bus bars.
Three power distribution solutions are available depending on the size of the intended deployment (see table).
Power Enclosures Supported
Power Enclosures SupportedPower Enclosures Supported
Power Enclosures Supported
Server Blade Enclosures
Server Blade EnclosuresServer Blade Enclosures
Server Blade Enclosures
Supported
SupportedSupported
Supported
Max. Rack Space Occupied
Max. Rack Space OccupiedMax. Rack Space Occupied
Max. Rack Space Occupied
Scalable Bus Bar
Scalable Bus BarScalable Bus Bar
Scalable Bus Bar
1 or 2
up to 5
36U
Mini Bus Bar
Mini Bus BarMini Bus Bar
Mini Bus Bar
1 or 2*
up to 3
24U
Power Bus Box
Power Bus BoxPower Bus Box
Power Bus Box
1 1
9U
NOTE*:
NOTE*:NOTE*:
NOTE*:
Dual power input kit for mini bus bar option (364565-B21) required to support two power enclosures.
NOTE:
NOTE:NOTE:
NOTE:
To support a full 42U rack of BL p-Class server blades, use two stacked pairs of mini bus bars.
Required Power Source
Required Power SourceRequired Power Source
Required Power Source
Two 30-Amp redundant power feeds per power enclosure
Connectors:
NEMA receptacles
NA 1-phase L6-30, 250v, 30A 3-wire
NA 3-phase L15-30, 250V, 30A, 4-wire
1.
For cabling information, refer to the website at:
http://www.hp.com/go/servers/
QuickSpecs
ProLiant BL30p
ProLiant BL30pProLiant BL30p
ProLiant BL30p
Standard Features (Power System and Rack Information)
DA - 11958 Canada — Version 2 — June 29, 2004
Page 14