Component Testing Information
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to washer before servicing, unless
testing requires it.
November 2000 3 RT3100016 Rev. 0
Illustration Component Test Procedure Results
R0000014 Brake pad kit If washtub does not stop spinning
within seven seconds after opening
loading door.
If brake pads make noises.
Replace all three brake pads.
Apply a thin layer of silicone (26594P) on
pads, see Service Bulletin
“ASQ
−
213
−
B”
40014401
94v-0
Q3
40014401
PCL-13
R21
C6
R22
R20
D6 R12
R18
D3
C1
C2
Q1
R19
+
R8
U1
D4
R4
TL-C
R23
R10
R9
R24
R14
MADE IN
MEXICO
R15
R17
R13
R7
R5
R6
C5
1
R
ACT control board Rotate temperature switch to
Sensor Wash Warm/Cold
Regulated Cycle
Both valves activates for 55
seconds
±
15 seconds. ..................
Only HOT valve is activated. ..........
Control board is working
Control board has failed, replace control
board.
40095001 Motor Type of motor:
Two speed
See following section “Internal Motor
Diagram and Schematic” for correct
wiring contacts.
40040301 Drain pump Verify drain pump is not clogged or
damaged.
Remove clog and verify proper operation.
Replace drain pump if damaged.
40032701 Transmission
assembly
Type of transmission:
710 rpm
Externally identical, must be identified by
part number.
If transmission locks-up, replace.
40053601 Drive belt Type of drive belt:
710 rpm
Refer to “Parts Manual” for proper
pulley size.
Refer to “Parts Manual”, to verify which
drive belt and pulley size is required.