Installation Instructions
REMOVE PACKAGING AND PARTS
/D\WKHFDUWRQRQUHDU
face and break open the
bottom flap.
6HWWKHFDUWRQXSULJKW
with all four bottom flaps
outward.
/LIWFDUWRQXSDQGRIILFH
maker.
5HPRYHDOOWDSHDQG
packaging material from the outside and inside
of the cabinet.
WATER FILTRATION SYSTEM
Install Water Filter
1. Locate the accessory packet in the ice maker and
remove the water filter.
2. Remove the cover from the water filter. Be sure the
O-rings are still in place after the cover is removed.
3. Locate the water filter compartment on the right-
hand side of the ice maker controls.
4. Align the alignment pin on the side of the filter
with the cutout channel in the control housing and
insert filter.
5. Turn filter clockwise until it locks into the housing.
NOTE: If the filter is not correctly locked into place,
the ice maker will not produce ice.
POWER SUPPLY
WARNING : (Please read carefully).
FOR PERSONAL SAFETY, THIS APPLIANCE MUST
BE PROPERLY GROUNDED. Failure to follow these
instructions can result in death, fire or electrical
shock.
AVERTISSEMENT :
(S’il vous lisez avec soin). POUR VOTRE SÉCURITÉ,
CET APPAREIL DOIT ÊTRE CORRECTEMENT MIS À
LA TERRE. Le non-respect de ces instructions peut
causer la mort, un incendie ou un choc électrique.
Do not use an extension cord or adapter plug with
this appliance. Follow National Electrical Code or
prevailing local codes and or di nanc es.
This ice maker must be supplied with 115V, 60Hz,
and connected to an individual, properly grounded
branch circuit, and protected by a 15 or 20 amp
circuit breaker or time delay fuse.
$SURSHUO\JURXQGHGWKUHHSURQJRXWOHWVKRXOGEH
located within reach of the ice maker’s 66” long
power cord. For a built-in installation, locate the
receptacle in the shaded area shown.
IMPORTANT: (Please read carefully).
The power cord of this appliance
is equipped with a three-prong
(ground ing) plug that mates with a
standard three-prong grounding wall
re cep ta cle to minimize the possibility
of electric shock. The customer
should have the wall receptacle and circuit checked
by a qualified electrician to make sure the re cep ta cle
is properly ground ed and has the correct polarity.
:KHUHDVWDQGDUGWZRSURQJZDOOUHFHSWDFOHLV
encountered, it is the personal re spon si bil i ty and
obligation of the customer to have it replaced with
a properly grounded three-prong wall receptacle.
Do not, under any circumstances, cut or remove
the third (ground) prong from the power cord.
DO NOT USE AN EXTENSION CORD.
6
Cover
O-Rings
Alignment Pin
Alignment
Arrow
8QORFNV\PERO
Alignment Pin
Lock symbol
Cutout channel in
control housing