Dil ID: 7
Dil Adı: french
Dil Kodu: fr6
Dünyanın En Büyük
Elektronik Bilgi Kütüphanesi



18 U25339-J-Z126-1-7600
Control panel on the global storage cabinet Controls and indicators
POWER COMPLETE
This green light is lit up after the system power controller has terminated the switching
on sequence without any errors. The light is extinguished when the POWER OFF button
is pressed.
SSU CHECK
The display illuminates if there is an error in global storage. The buzzer sounds at the
same time.
BATTERY STATUS
These indicators indicate the state of the backup battery:
Potentiometer for volume
This is used to set the volume of the buzzer.
Potentiometer for brightness
This is used to set the brightness of the LCD display.
4.2.2 Button functions
LCD BACK LIGHT
The LCD display STATUS (background) is illuminated for five minutes when you press
this button. The lights go out immediately when you press this button again.
CANCEL / ALARM STOP
When this button is pressed, the buzzer in the control panel is stopped and the SSU
CHECK light is extinguished. If another malfunction occurs after the light is extin-
guished, e.g. a machine error or a malfunction in the power supply, the buzzer and the
SSU CHECK light are reactivated.
Name Color Meaning Measure
BS green Backup battery is installed
BBON green Backup battery is active
BI green Backup battery is not available
DI green Data in the global memory are invalid
DS green Indicator is not in use
BE yellow Error in backup battery operation Call service dept.
BF yellow Error in the backup battery Call service dept.