Dil ID: 7
Dil Adı: french
Dil Kodu: fr6
Dünyanın En Büyük
Elektronik Bilgi Kütüphanesi



U25339-J-Z126-1-7600 17
Controls and indicators Control panel on the global storage cabinet
The information is shown on the LCD display in the following format:
Meanings:
Line Display field Display Meaning
Line 1 Maintenance
mode
none User mode
CE Maintenance mode
CM Hot system maintenance mode
Test mode none Normal mode
T Test mode
SSU status Pnnn SSU switched off, battery not active: P000
SSU switched off, battery active: P001
P codes during the switching on and initial-
ization phase as well as when switching off:
P002 to P379
Bnnn nnn shows the time in hours since the backup
battery became active after the network
failure.
CHK SSU in check stop state
CNCT SSU connected to a cluster
Line 2 FLAG Code none Normal state
FFFFFFFFFFFFFFFF Message or error code:
this display is for the purposes of the service
department.
FFFFFFFFFFFFFFFF
CC C CCCC
CM
CE
T
Pnnn
Bnnn
CHK
CNCT
Line 1
Line 2
FFFFFFFFFFFFFFFF
Displays in line 1
Displays in line 2
STATUS