Table 3-2. System Beep Codes (continued)
Code Cause
Corrective Action
1^-2
1-3-3
1-3-4
No memory installed
Chip or data line failure in
the first 64 KB of main
memory
Odd/even logic failure in
the first 64 KB of main
memory
Remove and reseat the DIM Ms. If the
problem persists, replace the DIMMs. See
"Adding Memory" in Chapter 8 for instruc
tions on installing or removing DIMMs. If
the problem still persists, replace the sys
tem board. See Chapter 12, "Getting
Help," for instaictions on obtaining techni
cal assistance.
1-4-1 Address line failure in the
first 64 KB of main
memory
1-4-2 Parity failure in the first
64 KB of main memory
2-1-1
through
2-4-4
Bit failure in the first
64 KB of main memory
3-1-1
3-1-2
Slave DMA-register
failure
Master DMA-register
failure
Replace the system board. See
Chapter 12, "Getting Help," for instruc
tions on obtaining technical assistance.
3-1-3 Master interrupt-mask
register failure
3-1-4 Slave interrupt-mask
register failure
3-2-4 Keyboard-controller test
failure
Check the keyboard cable and connector
for proper connection. If the problem per
sists, run the Keyboard Test Group in the
Dell Diagnostics to determine whether the
keyboard or keyboard controller is faulty.
See Chapter 5, "Running the Dell Diagnos
tics." If the keyboard controller is faulty,
replace the system board. See Chapter 12,
"Getting Help," for instructions on obtain
ing technical assistance.
3-3-1 CMOS failure Run the System Set Test Group in the Dell
Diagnostics to isolate the problem. See
Chapter 5, "Running the Dell Diagnostics."
NOTE: For the full name of an abbreviation or acronym used in this table, see the abbreviation and
acronym list that precedes the Index.
3-10 Dell PowerEdgetSSO ^sterns Installation and Troubleshooting Guide