Issue Date: 2010-03-02 Page 1 of 23 Report Reference # E336418-A29-UL
2010-10-22
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
1
GENERAL
Pass
1.5 Components Pass
1.5.1 General Pass
Comply with IEC 60950 or relevant component
standard
(see appended table 1.5.1) Pass
1.5.2 Evaluation and testing of components Components certified to IEC
harmonized standard and
checked for correct
application.
Components, for which no
relevant IEC-Standard exist,
have been tested under the
conditions occurring in the
equipment, using applicable
parts of IEC 60950-1.
Components not certified are
used in accordance with their
ratings and they comply with
applicable parts of IEC 60950-
1 and the relevant component
Standard.
Pass
1.5.3 Thermal controls N/A
1.5.4 Transformers Transformers comply with the
relevant requirements of this
standard.
See annex C for compliance.
Pass
1.5.5 Interconnecting cables Interconnecting cables comply
with the relevant requirements
of this standard.
Pass
1.5.6 Capacitors in primary circuits ................................ : - X/Y capacitors complied with
IEC 60384-14: 1993.
- Line-to-line capacitors are
subclass X1 or X2.
- Primary-to-earth capacitors
are subclass Y1.
Pass
1.5.7 Double insulation or reinforced insulation bridged
by components
Pass
1.5.7.1 General Pass
1.5.7.2 Bridging capacitors Double Insulation bridged by a
single capacitor complying with
IEC 60384-14: 1993, subclass
Y1.
Pass