osition- and connection instructions
Electrical connection
The dishwasher is supplied with a lead and electrical plug for connection
to a 230 V earthed wall socket, which should be easily accessible and
protected by a 10 A fuse.
Permanent electrical installation must be carried out by an authorised
electrician or competent person.
Before any work is carried out on the dishwasher, it must be isolated
from the electric mains supply, for example by removing the plug
from the wall socket.
Test standard:
EN 50242 and EN 60704
Rated capacity:
6 place settings accordance EN 50242
Loading of basket:
see chapter ”Loading the dishes”
Test program:
Eco 55° C
Rinse aid (Type III):
setting 3
Water pressure:
minimum 0,8 bar, maximum 10 bar
Waste water outlet:
install according to figure below
Detergent (IEC Type B): 9 gram in the dispenser + 5 gram in the pre-
wash dispenser
Information for test centres
The salt container and rinse aid dispenser shall be filled in accordance
with this instruction manual.
Before conducting the measurements the dishwasher shall be operated