System Clock 11
System Clock The time settings may get lost when power is removed from the device
for durations greater than 30 days. Following an initial installation or
whenever power is removed from the device for an extended period of
time, it is recommended that the time setting be verified.
The time setting can be viewed using the show clock command in the
CLI. If the time is not accurate, the proper time setting can be defined
using the set clock command.
Service Access
Permissions
The Logical View allows permissions between a User group and a Service
definition to be individually allowed or denied. When the service access
permissions are changed, it will take 15 seconds for this change in policy
to take effect.
The policy change only applies to connections initiated after the access
permissions are changed. That is, connections currently established to the
application service are not affected when the permissions are altered.
Balance Profile
Configuration
You cannot change a balance profile health check while the health check
is assigned to a service although the Web interface allows you to attempt
this.
The definition of a Logical View > Balance Specification requires that a
health check type be selected. The Web interface currently allows an
attempt to modify the health check type for an existing Balance
Specification. This operation is prevented by the operational firmware
with the following indication:
Error: The Health check type cannot be changed for an existing Balance Profile
In order to change the health check type for a service, you must:
1 Unassign the servers using Server Assignments.
2 Create a new balance profile specification and select a different health
check type. Y
3 Apply the new specification to the desired application service.
4 Reassign the servers using Server Assignments.