10
MOTOR- AND PROGRAMFUNCTIONS
Out-of-balance check and spin drying
There are 2 different spin dry sequences, long and
short. Both consist of a preliminary spin, the
washing cycle and a main spin dry.
Before the preliminary spin the machine runs
a separating cycle at 100 rpm, and measures the
drum inertia on the way up and down. This checks
for out-of-balance. During this cycle the holder
may make violent movements although there is
nothing wrong.
In attemp to get balance the machine does a
maximum of 10 restarts. If the out-of-balance is
still too great in the final, tenth, attempt, the pro-
gram will continue without performing spin dry-
ing. This is indicated on the display after the pro-
gram has finished.
Restart point after interrupted start attempt
If a start has been interrupted due to excessive out-
of-balance, the motor runs for 1 cycle counter-
clockwise, and then another attempt is made.
Drain pump during long spin dry
The drain pump runs continuously for the first 6
minutes and then 50 seconds off, 10 seconds on,
50 seconds off, and so on for the remainder of
the respective cycle. If a restart takes place due to
excessive out-of-balance, the drain pump opera-
ting time is reset to zero.
Drain pump during short spin dry
The drain pump runs continuously for the who-
le cycle.
MOTORFUNKTIONS
Sequence Inlet valve Motor action
Pre-wash 1 Normal
Main wash 2 alt 3 Normal
Rinse 1 1 Normal
Rinse 2 1 Normal
Rinse 3 1+4 Normal
Wool 2 alt 3 Super gentle
Syntetic 2 alt 3 Normal
Spin. A Normal
Spin. B Normal
Motor actions
Normal: Clockwise 12 seconds on, 3 seconds off,
counterclockwise 12 seconds on, 3 seconds off,
49 rpm.
Super gentle: Clockwise 3 seconds on, 57 seconds
off, counterclockwise 3 seconds on, 57 seconds
off, 49 rpm.
Sequences
Spin A: Normal motor action clockwise and
counterclockwise followed by a clockwise peak
to 500 rpm, normal motor action clockwise and
counterclockwise followed by a clockwise spin for
210 seconds on 1000 rpm.
Spin B: Normal motor action clockwise and
counterclockwise followed by a clockwise peak
to 500 rpm, normal motor action clockwise and
counterclockwise followed by a clockwise spin for
15 seconds on 800 rpm.
Motor actions and inlet valve