Tag Definitions Appendix D
Slotx_GSR_GLP_NonRecoverableFault_A SINT Non-Recoverable Fault Processor A – Indicates a
nonrecoverable fault has been recorded by Safety
Processor A. See Table 12 on page 60 for a list of non-
recoverable fault codes.
Slotx_GSR_GLP_NonRecoverableFault_B SINT Non-Recoverable Fault Processor B – Indicates a
nonrecoverable fault has been recorded by Safety
Processor B. See Table 12 on page 60 for a list of non-
recoverable fault codes.
Slotx_GSR_GLP_GateOpenFault BOOL Gate Open Fault - Indicates the Gate inputs, S12,
S22, unexpectedly opened.
0 = No Fault
1 = Fault
Slotx_GSR_GLP_InvalidSwitchSetting BOOL Invalid Switch Setting Fault – The rotatory switch
configuration does not match the configuration
stored in the safety relay.
Slotx_GSR_GLP_LockRequestGateOpenFault BOOL Lock Request/Reset Gate Open Fault - Indicates
the gate was open during a lock or reset request.
0 = No fault
1 = Fault
Slotx_GSR_GLP_Overspeed_SL2 BOOL Over-speed SL2 Fault - Indicates the monitored
speed exceeded the configured maximum speed limit
settings for SL2.
0 = No fault
1 = Fault
Slotx_GSR_GLP_Overspeed_SL1 BOOL Over-speed SL1 Fault - Indicates the monitored
speed exceeded the configured maximum speed limit
settings for SL1.
0 = No fault
1 = Fault
Slotx_GSR_GLP_LockRequestHeldOn BOOL Lock Request Held On Fault – Indicates the lock
request signal On (1) for longer than the maximum
time of 3000 ms.
0 = No fault
1 = Fault
Slotx_GSR_GLP_UnLockRequestHeldOn BOOL Unlock Request Held On Fault – Indicates the
unlock request signal On (1) for longer than the
maximum time of 3000 ms.
0 = No fault
1 = Fault
Table 11 - GSR GLP Module Input Tags