A–2
Output V
oltage (V)
Adjustable from 0V to input voltage
Output Frequency (Hz)
0 to 240 Hertz Programmable
Efficiency (%)
97.5% (T
ypical)
Transient Protection
Standard 2 kV (Optional 6 kV using MOV module). See accessories on page A-5.
Enclosure
IP 20
Ambient Temperature 0_C to 50_C
Storage T
emperature Ć40_C to 85_C
Relative Humidity
0 to 95% (non condensing)
Vibration
1.0 G Operational - 2.5 G Non-operational
Shock
15 G Operational - 30 G Non-operational
Altitude 1,000 m (3,300 ft.) without derating
Control Input Type
For dry contact closure input - the controller has an internal 12V power supply that provides
10-mA (typical) current flow.
Also accepts open collector/solid state input with maximum leakage current of 50 mA
Start, Stop, Forward/Reverse
Configurable inputs for 2 or 3 wire control
SW1, SW2, SW3
Configurable Inputs for control of 8 preset speeds and 2 Accel/Decel times
Approvals
UL508C 89/336/EEC
À
CSA 22.2
Designed to meet these standards
IEC 146-1-1
FCC Class A
À
and B
À
VDE 0871
À
and 0875
À
External Speed Potentiometer
1K to 10K Ohms, 2 W
atts Minimum
Analog Input (4 to 20mA)
Input lmpedance 250 Ohms
Analog Input (-10 to +10 V DC)
Input Impedance 100 K Ohms
Programmable Output
(Form C Relay contact)
Resistive rating: 0.4A @125V AC, 0.2A @ 230 V AC, 2A @ 30V DC
Inductive rating: 0.2A @ 125V AC, 0.1A @ 230V AC, 1A @30V DC
À
With external filters.