1 Service
11 Info SP: XXXX Date the software was programmed (Year_Week)
CM: XXXX Date of manufacture of the control unit (Year_
Week)
SW: Software version
SW: Software version
NC: Number of cycles/programmes run
NC 1: Number of cycles for Programme 1
NC 2: Number of cycles for Programme 2
NC 3: Number of cycles for Programme 3
NC 4: Number of cycles for Programme 4
NC 5: Number of cycles for Programme 5
NC 6: Number of cycles for Programme 6
NC 7: Number of cycles for Programme 7
NC 8: Number of cycles for Programme 8
NC 9: Number of cycles for Programme 9
NC 10: Number of cycles for Programme 10
12 Fault
scenarios
Fault 1 Shows current fault. The display shows Fault
name_Programme number_Number of cycles_
Index number.
Example: Thermistor fault_Pr5_9_(1)
Error messages are erased from the system during
a total reset.
Fault 2
Fault 3
13
Diagnostics
Test
Test valve 1 Inlet valve 1 is open.
Test valve 2 Inlet valve 2 is open.
Test valve SM Inlet valve 1 and 2 are open.
Test valve 3 Inlet valve 3 is open.
Test heater Heater on up to max. 60°C.
Test motor The motor normally runs at 49 rpm.
Test drain The drainage pump runs.
Test spin The machine runs a spin sequence, the drainage
pump runs.
Test door The door lock is activated and the door opens.
Returns to the programme menu.
14 Total
reset
The machine is restored to its factory settings.
Returns to the programme menu after Total reset.
15 ABC
reset
The custom programmes (Pr20-Pr22) are reset.
Returns to the programme menu after ABC reset.
Return
Press the Key button (S5) to return to 1 Service.
2 Settings
21 Water
inlet
Cold
Hot
22 Max
RPM
400 rpm
This function only works for programmes
Pr1-Pr19.
600 rpm
800 rpm
1000 rpm
1200 rpm
1300 rpm
1400 rpm
1500 rpm
1600 rpm
23 Drain Pump
Valve
Service menu content