11
Procedures (continuation)
Disconnect boiler heating element
Remove the hose at the back of the boiler
Pull off the thermo sensor that is located on the boiler
Put the machine onto the left side
Remove the base cover
Pull off the two black hoses on the air chamber (air trap) of the
boiler
Put the boiler onto the machine
Unplug the diffusion sensor
Move the wire hose clip that is located at the hose of the lower
distributor upwards
On the collector, pull off the hose that leads to the Mediamat