Dil ID: 1
Dil Adı: english
Dil Kodu: en1 Winterhalter Brand's Products
Dünyanın En Büyük
Elektronik Bilgi Kütüphanesi



4343434343
Disposal
41
16 Disposal
Contact your dealer so that as many of the materials contained in the machine as possible can be recycled.
17 Technical data
17.1 Technical data
Machine type Width [mm] Depth [mm] Height* [mm]
UC-S 460 602.5 715
UC-M 600 602.5 715
UC-L 600 602.5 810
UC-XL 600 641.5 810
* On machines with integrated exhaust air heat recovery (Energy) the height dimension increases by 85 mm.
Voltage see rating plate
Total connected load see rating plate
Fusing see rating plate
Water pressure (flow pressure) 80 – 600 kPa (100 kPa = 1 bar)
Water inlet temperature max. 60°C
UC-…-Cool: cold water
UC-…-Energy: cold water
Factory settings for hygiene logbook
Event Screen display Stored in hygiene logbook
Rinse aid container empty yes yes
Detergent container empty yes yes
The service interval has expired no no
Other events are possible on request
Screen factory settings
Event Possible selections Factory setting
Screen saver yes/no yes
Screen saver appears after 0 – 63 minutes 10 minutes
Screen darkens yes/no yes
Screen darkens after 0 – 63 minutes 20 minutes
Acoustic signal when buttons pressed yes/no yes
Machine is ready for operation before
rated temperatures have been reached
yes/no yes
17.2 Emissions
Noise
The emission sound pressure level at a work station
L
pAeq
as per EN ISO 11202 is < 60 dB(A)
Exhaust air
The ventilation system must be configured in compliance with VDI Guideline 2052.