MODEL SS-4 -
MODEL SS-5 -
Water Alert detector - No audible alarm...Provides
isolated dry relay contacts (DPDT) which transfer and
hold when activated. Self-resets.
Powering options -
- 9v Alkaline Battery (Qty.2)
- PS-3 Power Supply (Pg. 25)
- Voltage Module (Pg. 26)
Audible alarm -
- None
Relay contacts -
- DPDT ( 2- Form C)
- 28 VDC@ 1 amp. MAX.
(For high power applications
see p.26 model PR-WM)
Power draw -
- 1ma @ 9vdc (activated)
Powering options -
- 9v Alkaline Battery (Qty.2)
- PS-3 Power Supply (Pg. 25)
- Voltage Module (Pg. 26)
Audible alarm -
- 100db @ 3 feet
- 10 day alarm duration
(Battery operation)
Relay contacts -
- DPDT ( 2- Form C)
- 28 VDC @1 amp. MAX.
(For high power applications
see p.26 model PR-WM)
Power draw -
- 25ma @ 9vdc (activated)
Water Alert detector provides audible alarm and
isolated dry relay contacts (DPDT) which transfer
and hold when activated. Self-resets.
- Used in applications where tie-in to an existing alarm panel is desired (Building
Management System, etc.) and no audible alarm is necessary. Also ideal for extremely
harsh environments and can control valves, pumps and other electrical equipment.
- Used in applications where tie-in to an existing alarm panel is desired (Building
Management System, etc.). Can also be used to control valves, pumps and other
electrical equipment.
MODEL SS-2100 -
Water Alert detector used to tie-into all
Dorlen’ Series 2100 Monitors
Powering options -
- Powered from Monitor (Pg. 11)
Audible alarm -
- 85db @ 3 feet
Relay contacts -
-None
Power draw -
- 20ma @ 9vdc (activated)
- Used in applications where a Dorlen Series 2100 Monitor / Power Supply is
desired.
(Model XSS-4 when using
optional Sensor Cable)
(Model XSS-5 when using
optional Sensor Cable)
(Model XSS-2100 when using
optional Sensor Cable)
6
WATER LEAK DETECTION SYSTEMS "SS" Models