WATER INLET VALVES
Refer to page 4-8 for the procedure for servic-
ing the water inlet valves.
1. Unplug washer or disconnect power.
2. Disconnect the wire connectors from the
water inlet valve you are testing.
3. Set the ohmmeter to the R X 1 scale.
4. Touch the ohmmeter test leads to the
water inlet valve solenoid terminals. The
meter should indicate between 75 and
125 Ω.
DOOR SWITCH
Refer to page 4-10 for the procedure for servic-
ing the door switch.
1. Unplug washer or disconnect power.
2. Disconnect the wire connectors from the
door switch terminals.
3. Set the ohmmeter to the R X 1 scale.
4. Touch the ohmmeter test leads to door
switch terminals 1 and 3. The meter should
indicate between 650 and 850 Ω.
1
3
2
1
3
2
650-850 Ω