Dil ID: 6
Dil Adı: turkish
Dil Kodu: tr10tayfun Unify Markası'nın Ürünleri
Dünyanın En Büyük
Elektronik Bilgi Kütüphanesi



SHB_PNG-Konfig.fm
A31003-M2000-M103-2-76A9, 07/2014
Alarm and Emergency Call Configuration, Administrator Documentation
3-10
Configuration and activation
Configuration menu
8. Confirm with Save.
Escape Alarm
The Escape Alarm can be activated optionally. It is triggered if the sensors identify undue
violent movement of the handset over a defined configurable period of time.
For more information on alarm destinations please refer to Chapter 4, "Control ports and alarm
destinations".
Procedure:
1. Select the Additional Features icon in the main menu.
2. Select Configuration.
3. Enter the five-position service PIN and confirm with OK.
4. Select one of the three operating modes.
5. Select Alarms.
6. Select Escape Alarm.
7. Change the values of the following parameters:
Alarm Destination
BM -
1
112
AM/PNG (up to 32 digits) (blank)
1 The alarm destination is the same in Basic Mode of the M3 Plus for all alarms and is entered under "General Settings".
Parameters Operating Mode Value Range Standard Value
Activation BM/AM/PNG On/off Off
Response Time
BM/AM 10 ... 900 s 30 s
PNG 10 ... 90 s 30 s
Prealarm Time
BM/AM 0 ... 300 s 15 s
PNG 0 ... 30 s 15 s
Empfindlichkeit BM/AM/PNG Low / Medium / High Medium
Alarm Destination
BM -
1
1 The alarm destination is the same in Basic Mode of the M3 Plus for all alarms and is entered under "General Settings".
112
AM/PNG (up to 32 digits) (blank)
Table 3-7 Parameter – Escape Alarm
Parameters Operating Mode Value Range Standard Value
Table 3-6 Parameter – Time Alarm