394
3300 ICP Technician’s Handbook
ACD Agents
1
350 200 80/100 350 350 50 50 50
IP Trunks per
controller
2000 2000 2000 2000 2000 2000 2000 2000
Attendant Consoles 24 16 8 24 24 8 8 8
IP Devices LX-1400
/700
250 100/200
350 / 1500
4
5600 100 150 100
/300
5
Programmable Key
Modules
75 75 75 75 75 75 75 75
Notes:
1
A combination of IP and DNI phones (no DNI in the CX/CXi, CX II/CXi II, or AX, or MXe
Server). Refer to 3300 ICP Engineering Guidelines for details.
2
The largest number is available only with the 192 channel PSTN gateway configuration.
3
R2 NSU only
4
Maximum 300/1400 IP users
5
The larger number is for light traffic (Hospitality sites) only.
6
The AX controller uses DSP echo cancellers (40 channels in total) in its default
configuration, but can use the 128-channel module to increase capacity. When the
128-channel module is installed, the echo canceller channels on the embedded DSPs
revert to telecom resource use.
Table 121: Hard Drive Capacities
Capacity Mitel Part Number Vendor Vendor Reference ID
40 GB
50004750 Maxtor
6E040L0
6K040L0
80.0 GB
50005686
Hitachi
0Y30001
0Y30003
Seagate ST380215A
82.3 GB
50005452 Hitachi
0A302210
0A32721
0A34078
Table 120: 3300 ICP Hardware Capacity (continued)
Parameter
Name
LX/700
User
250
User
100 User/
MX
MXe Base/
Expanded
MXe
Server
CX /
CXi
CX II /
CXi II
AX
Page 2 of 2