System Unit
System UnitSystem Unit
System Unit
Dimensions
DimensionsDimensions
Dimensions
(H x W x D)
(with bezel)
3.44x 17.64 x 27.50 in (8.75 x 44.80 x 69.88cm)
Weight
WeightWeight
Weight
(approximate)
Maximum
MaximumMaximum
Maximum
(all hard drives, power
supplies and processors
installed)
51.5 lb (19.22 kg)
Minimum
MinimumMinimum
Minimum
(one hard drive, power
supply and processor
installed)
35.0 lb (13.06 kg)
Input
InputInput
Input
Requirements
RequirementsRequirements
Requirements
(per power supply)
Rated Line Voltage
Rated Line VoltageRated Line Voltage
Rated Line Voltage
100 - 240 VAC
Rated Input Current
Rated Input CurrentRated Input Current
Rated Input Current
9.10 A (at 100 VAC),
4.5 A (at 200 VAC)
Rated Input Frequency
Rated Input FrequencyRated Input Frequency
Rated Input Frequency
50 to 60 Hz
Rated Input Power
Rated Input PowerRated Input Power
Rated Input Power
910 W (at 100 VAC),
900 W (at 200 VAC)
BTU Rating
BTU RatingBTU Rating
BTU Rating
Maximum
MaximumMaximum
Maximum
3107.82 BTU/hr (at 100 VAC),
3073.67 BTU/hr (at 200 VAC)
Power Specifications
Power SpecificationsPower Specifications
Power Specifications
To review typical system power ratings use the Power Calculator which is
available via the online tool located at URL:
http://h30099.www3.hp.com/configurator/calc/
Power%20Calculator%20Catalog.xls
Click on the system of interest. Example: DL180 G5
Follow the instructions of the next screens.
Power Supply Output
Power Supply OutputPower Supply Output
Power Supply Output
(per power supply)
Rated Steady-State Power
Rated Steady-State PowerRated Steady-State Power
Rated Steady-State Power
750 W (at 100 VAC),
750 W (at 200 VAC)
Maximum Peak Power
Maximum Peak PowerMaximum Peak Power
Maximum Peak Power
750 W (at 100 VAC),
750W (at 200 VAC)
System Inlet Temperature
System Inlet TemperatureSystem Inlet Temperature
System Inlet Temperature
Operating
OperatingOperating
Operating
50° to 95°F (10° to 35°C) at sea level with an
altitude derating of 1.8°F per every 1000 ft
(1.0°C per every 305 m) above sea level to a
maximum of 10,000 ft (3050 m), no direct
sustained sunlight. Maximum rate of change is
18°F/hr (10°C/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if operating
with a fan fault or above 86°F (30°C).
Non-operating
Non-operatingNon-operating
Non-operating
-22° to 140° F (-30° to 60° C). Maximum rate of
change is 36° F/hr (20° C/hr).
Relative Humidity
Relative HumidityRelative Humidity
Relative Humidity
(non-condensing)
Operating
OperatingOperating
Operating
10 to 90% relative humidity (Rh), 82.4° F (28° C)
maximum wet bulb temperature, non-
condensing.
Non-operating
Non-operatingNon-operating
Non-operating
5 to 95% relative humidity (Rh), 101.7° F (38.7°
C) maximum wet bulb temperature, non-
condensing.
QuickSpecs
HP ProLiant DL180 Generation 5 (G5)
HP ProLiant DL180 Generation 5 (G5)HP ProLiant DL180 Generation 5 (G5)
HP ProLiant DL180 Generation 5 (G5)
Technical Specifications
DA - 12903 Worldwide — Version 10 — July 14, 2008
Page 29