
Four Drive Serial ATA (SATA) Models
Four Drive Serial ATA (SATA) ModelsFour Drive Serial ATA (SATA) Models
Four Drive Serial ATA (SATA) Models
NOTE:
NOTE:NOTE:
NOTE:
To upgrade from 4 Non-Hot Plug SATA hard drives to 4 Hot Plug SATA/SAS hard drives the addition of a storage controller
and one Internal SATA/SAS cable (464830-B21) are required. To upgrade to 8 Hot Plug SATA/SAS hard drives, the addition of a
storage controller and two Internal SATA/SAS cables (464830-B21) are required.
NOTE:
NOTE:NOTE:
NOTE:
To upgrade to server models supporting 12 hard drives; you must start with HP ProLiant DL180 CTO Chassis (P/N 457649-
B21). Please see the Configuration To Order section below.
HP DL180 G5, E5420
HP DL180 G5, E5420HP DL180 G5, E5420
HP DL180 G5, E5420
2.50GHz,(QC) 1GB (1P)
2.50GHz,(QC) 1GB (1P)2.50GHz,(QC) 1GB (1P)
2.50GHz,(QC) 1GB (1P)
456830-xx1
HP DL180 G5, E5405
HP DL180 G5, E5405HP DL180 G5, E5405
HP DL180 G5, E5405
2.00 GHz,(QC) 1GB (1P)
2.00 GHz,(QC) 1GB (1P)2.00 GHz,(QC) 1GB (1P)
2.00 GHz,(QC) 1GB (1P)
456831-xx1
Processor
ProcessorProcessor
Processor
One of the following
depending on model
Quad-Core Intel® Xeon® processor E5420 (2.50 GHz, 80W, 1333 MHz
FSB)
Quad-Core Intel® Xeon® processor E5405 (2.00 GHz, 80W, 1333 MHz
FSB)
Cache Memory
Cache MemoryCache Memory
Cache Memory
12MB (2 x 6MB) Level 2 cache (5400 sequence)
Memory
MemoryMemory
Memory
1 GB (1 x 1 GB) PC2-5300 DIMMs (DDR2-667) with Advanced ECC
capabilities
Network Controller
Network ControllerNetwork Controller
Network Controller
One HP NC105i PCI-E (embedded)
Storage Controller
Storage ControllerStorage Controller
Storage Controller
Embedded SATA Raid Standard
Hard Drive
Hard DriveHard Drive
Hard Drive
None ship standard (up to 8 Hot Plug SATA or SAS drives supported
standard with the addition of a controller and cable. 12 drive models
supported via CTO only.)
Internal Storage
Internal StorageInternal Storage
Internal Storage
BTO internal storage capacity of up to:
8.0TB (8 x 1TB Hot Plug 3.5" SATA hard drives)
8.0TB (8 x 1TB Hot Plug 3.5" SAS hard drives)
Optical Drive
Optical DriveOptical Drive
Optical Drive
DVD-ROM, DVD RW (Optional)
Form Factor
Form FactorForm Factor
Form Factor
Rack (2U)
NOTE:
NOTE:NOTE:
NOTE:
Server models supporting 4 hard drives are Non-Hot Pluggable.
Smart Array Controller must be added for Hot Plug drive capability.
NOTE:
NOTE:NOTE:
NOTE:
SAS (Serial Attach SCSI) capability requires the addition of a Smart
Array or HBA Controller card.
Country Code Key
Country Code KeyCountry Code Key
Country Code Key
xx = 00
U.S.
xx = 20
Brazil
xx = 29
Japan
xx = 37
APD
xx = 42
Europe
xx = AA
PRC
QuickSpecs
HP ProLiant DL180 Generation 5 (G5)
HP ProLiant DL180 Generation 5 (G5)HP ProLiant DL180 Generation 5 (G5)
HP ProLiant DL180 Generation 5 (G5)
Models
DA - 12903 Worldwide — Version 10 — July 14, 2008
Page 10