Important Information About the SPARC Enterprise T5120 and T5220 Servers 39
Where MSGID is one of the PSH Message ID's listed above and displayed by the
ALOM showfaults command.
Once the faulty DIMM(s) have been replaced and the PSH fault has been cleared, the
entry in showfaults will be deleted and the fault recorded in the motherboard
FRUID will be cleared.
If Socketed EEProm (SCC) is Changed, SP Does Not Always
Read Some SP Properties From New EEProm (CR 6596430)
If the SP configuration variable sc_backupuserdata is set to false, the following
user configuration values are not backed up to the Socketed EEProm:
if_emailalerts, mgt_mailhost, mgt_mailalert, sc_customerinfo,
sc_powerondelay, sc_powerstatememory, sc_backupuserdata
Workaround: Manually copy the preceding user settings before replacing the mother
board in a motherboard swap scenario. After the swap is complete, manually set the
user parameters.
If All Platform Identity Checks Fail (CR 6593801)
When all platform identity checks fail, system power on should be disabled. If
enough of the FRUs are corrupted, the system cannot determine its identity, which
makes certain components nonoperational and could crash the server.
Login to SP Times Out Intermittently (CR 6568750)
Logging into the SP could intermittently fail and timeout after 60 seconds. If this
error occurs, you see an error message similar to the following:
Workaround: None. This is not seen during normal login, only when logging in with
a script.
SUNSP00123456789F login: username
Password: password
Starting VBSC Server
VBSC server started..
Logging out after 60 seconds.