18 SPARC Enterprise T5120 and T5220 Servers Product Notes October 2007
The following formatting issues could be displayed in the prtdiag -v command
output:
Fans sensors – Missing spaces tab between Location and Sensor columns
Temperature sensors – DIMMs missing spaces tab between Location and Sensor
columns
LEDs – Location missing for SERVICE, LOCATE, ACT, PS_FAULT, TEMP_FAULT,
and FAN_FAULT DIMMs. Missing spaces tab between Location and LED. In
addition the locations of sensors have the first portion of their location truncated,
resulting in no location being reported for some items such as system status
LEDs.
To see this formatting information, use the showenvironment command in the
ALOM CMT compatibility CLI:
Solaris locator Command Not Working (CR 6564180)
The locator command sets or queries the state of the system locator if such a
device exists. Your server does have a locator LED. However, this command
incorrectly returns an error message similar to the following.
Workaround: To obtain locator LED information, use the following commands.
In the ALOM CMT compatibility CLI, to show the locator position:
In the ALOM CMT compatibility CLI, to set the locator LED to on or off:
In the ILOM CLI, to show the locator position:
sc> showenvironment - displays the system environmental status
# locator -n
’system’ locator not found
sc> showlocator
sc> setlocator on
OR
sc> setlocator off
-> show /SYS/LOCATE/