the appliance makes an unusual noise
during draining due to objects such as
safety pins, coins etc. blocking the
pump;
a problem with water draining is de-
tected (see chapter “What to do if...”
for more details).
WARNING!
Before opening the pump door,
switch the appliance off remove
the mains plug from the socket.
Proceed as follows:
1.
Unplug the appliance.
2.
If necessary wait until the water has
cooled down.
3.
Open the pump door.
4.
Pull flap forward to remove.
5.
Place a container close to the pump
to collect any spillage.
6.
Pull out the emergency emptying
hose, place it in the container and
remove its cap.
7.
When no more water comes out, un-
screw the pump cover by turning it
anti-clockwise and remove the filter.
Use pliers, if necessary. Always keep
a rag nearby to dry up any water
spillages when removing the cover.
Clean the filter under a tap, to re-
move any traces of fluff.
8.
Remove foreign bodies and fluff
from the filter seat and from the
pump impeller.
9.
Check carefully whether the pump
impeller rotates (it rotates jerkily). If
it doesn’t rotate, please contact your
Service Centre.
10.
Put the cap back on the emergency
emptying hose and place the latter
back in its seat.
11.
Replace the filter into the pump by
inserting it correctly into the special
guides. Screw the pump cover firmly
by turning it clockwise.
12.
Refit the flap and close the pump
door.