4. Disconnect the cabin heater harness connector (A) from
the Li-ion battery.
Touching high voltage components without wearing
appropriate Personal Protective Equipment (PPE) will
cause electrocution.
a. Use the following instructions to disconnect the
cabin heater harness connector.
To prevent electrocution, cover battery side of high
voltage connector with insulated tape.
: Insulated tape
5. Disconnect the Li-ion battery vehicle communications
connector (A) while turning it counterclockwise.
Touching high voltage components without wearing
appropriate Personal Protective Equipment (PPE) will
cause electrocution.
A
AAYIA0171ZZ
1
3
4
2
Pull back lock tab Press release and
pull connector
Disconnect connector
AAYIA0050GB
AAYIA0172ZZ
A
AAYIA0167ZZ
DG–41