Type
MUP-07 HE MUP-09 HE MUP-12 HE MUP-18 HE MUP-24 HE
Cooling capacity (W)
2300 2500 3200 5200 7000
Heating capacity (W)
2650 2750 3520 5700 7700
Circulating wind quantity (m
3
/h)
400 420 520 850 1000
Power source (V/Hz)
1 PH 220-240~/50 1 PH 220-240~/50
Rated input power (W)
Cooling
900 1000 1200 2090 2700
Heating
880 980 1250 2200 2800
Rated input current (A)
Cooling
4.3 4.4 5.5 9.5 13.5
Heating
4.1 4.1 5.7 10 14
Input power under worst conditions (W)
1280 1300 1720 3200 3800
Input current under worst conditions (A)
6.8 6.9 8.8 16 19
Name of refrigeration material
R407C R407C
Indoor unit
Size of shape (mm)
(thicknessxwidthxheigh)
210 x 745 x 250 312 x 1095 x 205
Net weight (Kg)
9.5 9.5 9.5 15 15
Noise (dBA)
26~38 26~38 26~41 39 ~ 49 39 ~ 49
Outdoor unit
Size of shape (mm)
(thicknessxwidthxheigh)
320 x 818 x 540 300 x 800 x 690
Net weight (Kg)
33 33 38 51 51
Noise (dBA)
≤ 50 ≤ 52 ≤ 53 ≤ 53 ≤ 57
Connecting pipe (mm)
Liquid tube
Ø 1/4" Ø 1/4" Ø 3/8"
Gas tube
Ø 3/8" Ø 1/2" Ø 5/8"
Range of voltage change (V)
198 ~ 253 198 ~ 253
Suitable room area (m
2
)
10 ~ 17 12 ~ 20 14 ~ 22 26 ~ 36 35 ~ 47
Notes: 1. Specifications are standard values calculated based on rated operating conditions ,they will vary in difference work condition