- 9 -
CM-680 INSTRUCTION MANUAL Ultra Stereo Labs, Inc.
- 6 -
CM-680 INSTRUCTION MANUAL Ultra Stereo Labs, Inc.
CM-680 Rear Panel
1. Main AC connector with fuse.
2. Amplifier outputs - connect to the power amplifier speaker outputs corresponding to Ls, Rs, Bsl, Bsr and Sw channels.
3. Amplifier outputs - connect to the power amplifier speaker outputs corresponding to Lh, Ll, Ch, Cl and Rh, Rl.
4. Amplifier level - this trimpot adjusts the level of the input lines coming from the Power Amplifiers.
5. HD-15 connector - connect to Ls/Rs amplifier.
6. HD-15 connector - connect to Bsl/Bsr amplifier.
7. Processor level - this trimpot adjusts the level of the input lines coming from the processor.
8. Crossover outputs - connect to the power amplifier inputs corresponding to Ls, Rs, Bsl and Bsr.
9. HD-15 connector - connect to Rl/Rh amplifier.
10. HD-15 connector - connect to Sw amplifier.
11. Crossover outputs - connect to the power amplifier inputs corresponding to Rl, Rh and Sw.
12. HD-15 connector - connect to Ll/Lh amplifier.
13. HD-15 connector - connect to Cl/Ch amplifier.
14. Crossover outputs - connect to the power amplifier inputs corresponding to Ll/Lh and Cl/Ch amplifier.
15. Optional input - connect these to the EX outputs of the processor
16. Bargraph level - this trimpot adjusts the sensitivity of the front panel VU Bargraph.
17. Main input - connect this to the main outputs of the processor.
18. AC Emergency power input - 12-16VAC, 0.5A
19. EX Selector switch - without EX, turn on 1-4 switches. With EX, turn on 5-8 switches.
This routes the correct Ls/Rs inputs to the CM-680 circuitry.
SWITCHES 1-4
ON
NORMAL Ls/Rs
12345678910111213 14 15 16
BYPASS
POWER
12VAC
@250mA
BARGRAPH
LEVEL
Ll+
Ll-
Lh+
Lh-
E
Cl+
Cl-
Ch+
Ch-
E
Rl+
Rl-
Rh+
Rh-
E
Swl+
Sw1-
Sw2+
Sw2-
E
Ll+
Ll-
Lh+
Lh-
E
Cl+
Cl-
Ch+
Ch-
E
Ls+
Ls-
Rs+
Rs-
E
Bsl+
Bsl-
Bsr+
Bsr-
E
E
Ll
Lh
COM
Cl
COM
Rl
Rh
COM
Ch
Ls
Rs
COM
Bsl
COM
Sw+
Sw-
COM
Bsr
Ll
Lh
Cl
Ch
Rl
Rh
Sw
1/2
Ls
Rs
Bsl
Bsr
CM-680
MONITOR/CROSSOVER
WARNING:
TO REDUCE THE
RISK OF FIRE OR ELECTRIC
SHOCK DO NOT EXPOSE THIS
APPLIANCE TO RAIN OR
MOISTURE. DO NOT REMOVE
COVER. NO USER SERVICE-
ABLE PARTS INSIDE. REFER
SERVICING TO QUALIFIED
PERSONNEL. FOR CONTINUED
PROTECTION AGAINST FIRE OR
SHOCK HAZARD REPLACE ONLY
WITH THE SAME FUSE TYPE
AND RATING.
ON
1234
AMPLIFIER
LEVEL
PROCESSOR
LEVEL
1
15
1
15
1
15
1
15
1
15
1
15
1
25
1
25
90-240VAC
50-60 Hz
115V
230V
17 18 19
ON
1 2 3 4
5678
ON
1 2 3 4
10
MONITOR INPUTS FROM
CROSSOVER OUTPUTS TO POWER AMPLIFIER INPUTS
SWITCHES 5-8
ON
EX CHANNELS
Ls/Rs/Bsl/Bsr
OPTIONAL INPUTS FROM PROCESSOR OUTPUTS
WARNING: UNITS EQUIPPED WITH
INTERNAL BYPASS CARD MUST
HAVE INTERNAL DIP
SWITCHES SET FOR
PROPER CONFIGURATION
MAIN INPUTS FROM PROCESSOR OUTPUTS
MAIN AUDIO OUTPUTS
OPTION CARD I/O
L
Biamp
C
Biamp
R
Biamp
Sw
Amp
Ls/Rs
Amp
Bsl/Bsr
Amp
DB-25 Cables
Cinema Processor
SWITCHES 1-4
ON
NORMAL Ls/Rs
BYPASS
POWER
12VAC
@250mA
BARGRAPH
LEVEL
Ll+
Ll-
Lh+
Lh-
E
Cl+
Cl-
Ch+
Ch-
E
Rl+
Rl-
Rh+
Rh-
E
Swl+
Sw1-
Sw2+
Sw2-
E
Ll+
Ll-
Lh+
Lh-
E
Cl+
Cl-
Ch+
Ch-
E
Ls+
Ls-
Rs+
Rs-
E
Bsl+
Bsl-
Bsr+
Bsr-
E
E
Ll
Lh
COM
Cl
COM
Rl
Rh
COM
Ch
Ls
Rs
COM
Bsl
COM
Sw+
Sw-
COM
Bsr
Ll
Lh
Cl
Ch
Rl
Rh
Sw
1/2
Ls
Rs
Bsl
Bsr
CM-680
MONITOR/CROSSOVER
WARNING:
TO REDUCE THE
RISK OF FIRE OR ELECTRIC
SHOCK DO NOT EXPOSE THIS
APPLIANCE TO RAIN OR
MOISTURE. DO NOT REMOVE
COVER. NO USER SERVICE-
ABLE PARTS INSIDE. REFER
SERVICING TO QUALIFIED
PERSONNEL. FOR CONTINUED
PROTECTION AGAINST FIRE OR
SHOCK HAZARD REPLACE ONLY
WITH THE SAME FUSE TYPE
AND RATING.
ON
1234
AMPLIFIER
LEVEL
PROCESSOR
LEVEL
1
15
1
15
1
15
1
15
1
15
1
15
1
25
1
25
90-240VAC
50-60 Hz
115V
230V
ON
1 2 3 4
5678
ON
1 2 3 4
MONITOR INPUTS FROM
CROSSOVER OUTPUTS TO POWER AMPLIFIER INPUTS
SWITCHES 5-8
ON
EX CHANNELS
Ls/Rs/Bsl/Bsr
OPTIONAL INPUTS FROM PROCESSOR OUTPUTS
WARNING: UNITS EQUIPPED WITH
INTERNAL BYPASS CARD MUST
HAVE INTERNAL DIP
SWITCHES SET FOR
PROPER CONFIGURATION
LR
LR
LR
LR
LR
LR
TERMINAL WIRING DIAGRAM
Figure 2
Figure 4
NOTE: There are two identical subwoofer outputs (SW1 & SW2)
which can be used