Checklist before installation
Table 6 Checklist before installation
Item Re
q
uirements
Result
Installation site
Ventilation
There is a minimum clearance of 10 cm (3.9 in)
around the inlet and exhaust vents for heat dissipation
of the router chassis.
A ventilation system is available at the installation site.
Temperature 0°C to 45°C (32°F to 113°F).
Relative humidity 10% to 95% (noncondensing).
Cleanness
Dust concentration 3 × 104 particles/m
3
.
No dust on desk within three days.
ESD prevention
The equipment and floor are well grounded.
The equipment room is dust-proof.
The humidity and temperature are in the acceptable
range.
Wear an ESD wrist strap and uniform when touching a
circuit board.
Place the removed memory module, CF card, or
HIM/MIM on an antistatic workbench, with the face
upward, or put it into an antistatic bag.
Touch only the edges, instead of electronic
components when observing or moving a removed
memory module, CF card, or HIM/MIM.
EMI prevention
Take effective measures to protect the power system
from the power grid system.
Separate the protection ground of the router from the
grounding device or lightning protection grounding
device as far as possible.
Keep the router far away from radio stations, radar
and high-frequency devices operating in high current.
Use electromagnetic shielding when necessary.
Lightning
protection
The grounding cable of the chassis is well grounded.
The grounding terminal of the AC power receptacle is
well grounded.
A port lightning arrester is installed. (Optional)
A power lightning arrester is installed. (Optional)
A signal lightning arrester is installed at the input end
of an external signal cable. (Optional)
Electricity safety
Equip an uninterrupted power supply (UPS).
In case of emergency during operation, switch off the
external power switch.