Figure 13 Connect the grounding cable to the grounding hole of router
NOTE:
The resistance reading should be smaller than 5 ohms between router chassis and the ground.
To guarantee the grounding effect, use the grounding cable provided with the router to connect to the
grounding strip in the equipment room as long as possible.
Installing interface modules
Removing a filler panel
Follow these steps to remove a filler panel:
Step1 Select the slot to install a HIM or MIM:
If a HIM is to be installed, remove the two filler panels in slot 1 or slot 2.
If a MIM is to be installed, remove the filler panel at the bottom of slot 1 or slot 2.
Step2 Remove the captive screws on the filler panel with a Phillips screwdriver.
Step3 Use a flat-blade screwdriver to prize the filler panel to remove it from the router.
Figure 14 Remove a filler panel