14
Figure 13 Connect the grounding cable to the grounding hole of router
NOTE:
• The resistance reading should be smaller than 5 ohms between router chassis and the ground.
• To guarantee the grounding effect, use the grounding cable provided with the router to connect to the
grounding strip in the equipment room as long as possible.
Installing interface modules
Removing a filler panel
Follow these steps to remove a filler panel:
Step1 Select the slot to install a HIM or MIM:
• If a HIM is to be installed, remove the two filler panels in slot 1 or slot 2.
• If a MIM is to be installed, remove the filler panel at the bottom of slot 1 or slot 2.
Step2 Remove the captive screws on the filler panel with a Phillips screwdriver.
Step3 Use a flat-blade screwdriver to prize the filler panel to remove it from the router.
Figure 14 Remove a filler panel