5
Steps to duplicate issue
1. Turn on C410x.
2. Turn on the host.
3. Check Device Manager. All the devices should be normal.
4. Reboot the host, C410x still keep power on status.
5. Check M2070Q in Device Manager. A Yellow Bang indicates a device error code 43.
Steps to clear "code 43" error
NOTE: An ipmi-utility loaded on a remote client is required to clear the "code43" error.
z IPMIUTIL Installation and Execution Under Windows OS
IPMIUTIL Download
IPMIUTIL Installation
Use IPMIUTIL To Control C410x
-Topology
-Set Client LAN IP Address
-Set C410x BMC IP Address
Verify IPMIUTIL C410x Control
Power GPGPU Slots On/Off To Clear Device Error “code 43”