Dil ID: 13
Dil Adı: romaina
Dil Kodu: ro5tayfun Produsele mărcii Nevion
Dünyanın En Büyük
Elektronik Bilgi Kütüphanesi



3GHD256256L / SD256256L Rev. E
nevion.com | 6
Synchronization handled by
Multicon2:
Connector(s):
- Analog Black&Burst, looped. Both PAL and NTSC
supported.
- Tri-Level, Looped. For HD signal formats only.
- Distribution of synchronization signals between
several routers.
BNC.
Configuration storage:
Removable compact flash card.
Other Features:
- Video switching synchronized on selectable field- and line number.
- Monitoring output on separate channel from each module. 32x1 switch on separate
level. (Same as EDH channel).
- SNMP agent, included with Multicon
3
.
Optional Features:
Redundant control:
Redundant Matrix Control using 2x Multicon2.
2.4 Video specifications
Supported formats:
Broadcast:
- 19.4Mbps and 143Mbps 2.97Gbps.
- DVB-ASI, SMPTE 259M, SMPTE 292M, SMPTE
310M and SMPTE 424M.
Electrical signal inputs, SD256256L:
Standard:
SMPTE 259M.
Data rate:
19.4Mbps, 143Mbps 540Mbps.
Connector:
75 ohm BNC female.
Impedance:
75 ohm nominal.
Return loss:
> 15dB (5 540MHz).
Cable equalization:
0 to 250m, typical Belden 8281.
Electrical signal inputs, 3GHD256256L:
Standard:
SMPTE 259M, SMPTE 292M and SMPTE 424M.
Data rate:
19.4Mbps, 143Mbps 2.97Gbps.
Connector:
75 ohm BNC female.
Impedance:
75 ohm nominal.
Return loss:
- >15dB (5MHz 1.5GHz);
- >10dB (1.5GHz 3GHz).
Cable equalization:
- 0 to 70m @ 3Gbps, typical Belden 1694A;
- 0 to 100m @ 1.5Gbps, typical Belden 1694A;
- 0 to 200m @ 270Mbps, typical Belden 1694A;
Electrical signal outputs, SD256256L:
Connector:
75 ohm BNC female.
Impedance:
75 ohm nominal.
Return loss:
> 15dB (5 540MHz).
Signal level:
800mVp-p ±10%.
Signal polarity:
Non-inverting with respect to inputs.
Electrical signal outputs, 3GHD256256L:
Connector:
75 ohm BNC female.
Impedance:
75 ohm nominal.
Return loss:
- >15dB (5MHz 1.5GHz);
- >10dB (1.5GHz 3GHz).
Signal level:
800mVp-p ±10%.
Signal polarity:
Non-inverting with respect to inputs.
Signal transition (both video formats):
3
GYDA-VX must be applied for SNMP agent if Syscon is used; only Multicon includes SNMP agent.