Unit Environment and Operating Conditions
Unit Environment and Operating ConditionsUnit Environment and Operating Conditions
Unit Environment and Operating Conditions
General Unit Operating Guidelines
Keep the computer away from excessive moisture, direct moisture and the extremes of heat and cold, to ensure that unit is
operated within the specified operating range.
Leave a 10.2 cm (4 in) clearance on all vented sides of the computer to permit the required airflow.
Never restrict airflow into the computer by blocking any vents or air intakes.
Do not stack computers on top of each other or place computers so near each other that they are subject to each other's re-
circulated or preheated air.
Occasionally clean the air vents on the front, back, and any other vented side of the computer. Lint, dust and other foreign
matter can block the vents and limit the airflow.
If the computer is to be operated within a separate enclosure, intake and exhaust ventilation must be provided on the
enclosure, and the same operating guidelines listed above will still apply.
Temperature Range
Operating: 50° to 95° F (10° to 35° C)*
Non-operating: -22° to 140° F(-30° to 60° C)
Relative Humidity
Operating: 10% to 90% (non-condensing at ambient)
Non-operating: 5% to 95% (non-condensing at ambient)
Maximum Altitude (unpressurized)
Operating: 10,000 ft (3048 m)
Non-operating: 30,000 ft (9144 m)
*
NOTE:
NOTE: NOTE:
NOTE:
Operating temperature is de-rated 1.0 deg C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level, no direct
sustained sunlight. Maximum rate of change is 10 deg C/Hr. The upper limit may be limited by the type and number of options
installed.
Power Supply
Power SupplyPower Supply
Power Supply
Power Supply
240 watt custom power supply - Active PFC
Operating Voltage Range
90 - 264 VAC
Rated Voltage Range
100 - 240 VAC
Rated Line Frequency
50/60 Hz
Operating Line Frequency Range
47 - 63 Hz
Rated Input Current
5A
System Heat Dissipation
Typical 340 btu/hr
(86 kg-cal/hr)
Maximum 1260 btu/hr
(318 kg-cal/hr
Power Supply Fan
80mm variable speed
Energy Star 3.0 Compliant
X
FEMP Standby Power Compliant
(<2W in S5 - Power Off)**
X
Power Consumption in ES Mode - Suspend
to RAM (S3) (Instantly Available PC)
< 3W
Environmental and Mechanical Engineering
Support Centre (EMESC) - Intranet Web
Site only
http://env-webserver.ccm.cpqcorp.net/EMESC/default.htm
**
NOTE:
NOTE: NOTE:
NOTE:
Power consumption in the Off/Apparent Off mode is measured and reported with the network interface controller "Wake
on LAN" feature disabled in F10 Setup (default is "enabled").
QuickSpecs
HP dc72 Blade Workstation Client
HP dc72 Blade Workstation ClientHP dc72 Blade Workstation Client
HP dc72 Blade Workstation Client
Technical Specifications
DA - 12705 Canada — Version 1 — February 12, 2007
Page 8