36 SPARC Enterprise T5120 and T5220 Servers Product Notes October 2007
Use fmdump -eV -u uuid with the UUID from the console message to determine if
the memory error is bogus. For example:
If the dram-esr is 0x1000000000008221, this CR 6592272 has been encountered.
The memory error can be ignored. No memory component replacement is necessary.
Use fmadm repair uuid to repair the bogus memory UE.
Temporary PCIe Link Failure During Boot Causes Fatal Error
Later (CR 6553515)
If a temporary PCIe link failure occurs during boot or any time later, the system
could fail. Note that if the link is up and working again before HV gets control, the
error is a problem in HV handling the leftover status. The following is an example of
the error message:
# fmdump -eV -u 59bf6418-5dcb-c1b0-b06a-f26fa18e4ee7 | \
grep dram-esr
dram-esr = 0x1000000000008221
{0} ok 4000 dload users/bog/rustn2obp_0502
Boot device:
/pci@0/pci@0/pci@1/pci@0/pci@2/network@0:,users|bog|rustn2obp_0502 File
and args:
FATAL: /pci@0/pci@0/pci@1/pci@0/pci@2/network@0: Last Trap: Non-
Resumable Error
TL: 1
%TL:1 %TT:7f %TPC:f0238978 %TnPC:f023897c
%TSTATE:820001600 %CWP:0
%PSTATE:16 AG:0 IE:1 PRIV:1 AM:0 PEF:1 RED:0 MM:0 TLE:0 CLE:0 MG:0 IG:0
%ASI:20 %CCR:8 XCC:nzvc ICC:Nzvc
%TL:2 %TT:3f %TPC:f024327c %TnPC:f0243280
%TSTATE:14414000400 %CWP:0
%PSTATE:4 AG:0 IE:0 PRIV:1 AM:0 PEF:0 RED:0 MM:0 TLE:0 CLE:0 MG:0 IG:0
%ASI:14 %CCR:44 XCC:nZvc ICC:nZvc
Normal GL=1
0: 0 0
1: f0200000 0
2: f0200000 0
3: fff78000 0
4: fec320fc 3ffe60000
5: f02833e4 3ffe60000
6: fee826c8 3ffe60600
7: fee817d8 f02432bc