Important Information About the SPARC Enterprise T5120 and T5220 Servers 17
Workaround: Reboot the system by dropping to the service processor (SP) and then
power cycle the host system with the following commands from the ALOM CMT
compatibility CLI:
Or, use the following commands from the ILOM CLI:
prtdiag Without -v Option Does Not Show Failures in
Output (CR 6586847)
The prtdiag command entered with no options does not display current failures
that are reported with the prtdiag -v option.
Workaround: Always use the -v option when running the prtdiag command.
Device Paths Wrong in prtdiag When Running e1000g
Driver (CR 6479347)
Device paths could be incorrect in the prtdiag utility for three out of four on board
network devices when running the e1000g driver.
Workaround: Force load all instances of the e1000g driver and then restart the picld
daemon. For example:
Another workaround is to use the -r option when booting or rebooting the system.
prtdiag -v Formatting Issues (CR 6587389)
Some of the information produced by the prtdiag(1M) utility is difficult to read
when the -v option is used. White space is missing between the first and second
fields in the report.
sc> poweroff
sc> poweron
sc> powercycle
-> stop /SYS
-> start /SYS
devfsadm -i e1000g
svcadm restart svc:/system/picl