Unit Configuration
BreezeCONFIG for BreezeACCESS VL and BreezeACCES 4900 User Manual
92
2.11.2.6 Discarded CIR/MIR
Internally Discarded MIR/CIR: Displays the number of data frames received
from the Ethernet port that were discarded by the MIR/CIR mechanism to
avoid exceeding the maximum allowed information rate.
2.11.2.7 Wireless Tx Events
Dropped Frames: The number of frames that were dropped because they
were retransmitted to the maximum allowed number of retransmissions
without being acknowledged.
Underrun: The number of times that a transmission was aborted because the
rate of submitting frames for transmission exceeds the available transmission
capability.
Others: The number of Tx events due to reasons other than those represented
by the other Tx Events counters.
Total: The total number of Tx events.
To reset Tx counters to zero:
Click
to revert the Tx counters to zero. This reverts to 0 also the
Traffic (Ethernet) and Rx counters.
To view a real-time graph of a counter:
Double-click on the value of a counter to view a real-time graph of the selected
counters. For more details refer to section
2.11.6 .