Chapter 3 - Parameters Summary Unit Control Page
AlvariCRAFT Device Manager 227 User Manual
3.15 Unit Control Page
Parameter Unit Range Default Run-Time
Unit Name AU, SU,
BU, RB
Up to 32 printable characters empty (none) Yes
Location AU, SU,
BU, RB
Up to 34 printable characters empty (none) Yes
Feature License String AU, SU,
BU, RB
Up to 64 hexadecimal digits NA No
Telnet Logout Timer
(min)
AU, SU,
BU, RB
1-999 (minutes) 5 (minutes) Yes
Default Configuration AU, SU,
BU, RB
No Default Setting Required
Complete Factory
Partial Factory
Complete Operator
Partial Operator
Cancel Pending Request
No Default setting
Required
No (except
Cancel
Pending
Request)
LED Operation Mode SU, BU,
RB
Normal
Threshold
Normal Yes
Type SU, BU,
RB
Disabled
RSSI
CRC
SNR
Modulation
Disabled Yes
Mode SU, BU,
RB
Equal or lower
Equal or higher
Equal
Equal Yes