Dil ID: 12
Dil Adı: portugal
Dil Kodu: pt7tayfun Produtos da Marca Xerox
Dünyanın En Büyük
Elektronik Bilgi Kütüphanesi



PREINSTALLATION
XEROX DOCUPRINT 96/DOCUPRINT 96MX LPS INSTALLATION PLANNING GUIDE 3-17
Printer U.S. and Canada,
60Hz:
International, 50 Hz
(WYE):
International, 50 Hz
(DELTA):
120/240 VAC or
120/208 VAC;
50 amp service;
NEMA 14-50R
KVA 7.3 (operating)
380, 400, 415 VAC
(3 phase, 5 wire);
20 amp service (WYE)
220, 230, 240 VAC (3 phase, 4 wire);
30 amp service (DELTA)
Audible noise Standby:
Operating:
Continuous: 52 dB (A)
Impulse: N/A
Continuous: 67dB (A)
Impulse: 72dB (A)
Optional peripheral cabinet U.S. and Canada,
60Hz:
International, 50 Hz:
208/240 VAC (1 phase) or
208/220 VAC (Line 1 to line 2);
15 amp service;
NEMA6-15R or
ANSI C73, 20R
KVA .9 in both standby and operating
200/230 VAC (1 phase);
15 amp service
Optional bypass transport The power requirements for the bypass transport module are all
satisfied by the DocuPrint 96/DocuPrint 96MX LPS printer module.
Agency certification UL, CSA, CE Mark, EC 950, VDE 0871 (Level AQ) and 0875, EEC
82/499, and CISPR 22 Class A.
Table 3-6. DocuPrint 96/DocuPrint 96MX Environmental and
electrical requirements (continued)
Environmental requirements