CAUTION:
DO NOT SWITCH ON THE COMPRESSOR IF THE CONDENSING UNIT IS
EQUIPPED WITH A LOW AMBIENT CONDITION KIT UNTIL THE UNIT HAS
BEEN PLUGGED IN FOR 24 HOURS.
2. Valve Operation (Condensing unit)
BACK POSITION FRONT POSITION MIDDLE POSITION
Fig. 5 ROTALOCK Valve Operation
BACK POSITION FRONT POSITION MIDDLE POSITION
Fig. 6 Base Valve Operation
1 – Process & Manometer; 2 – Receiver/Compressor Suction
3 – Liquid/Suction Line; 4 – Pressure Control
Back Position: Process and manometer port closed for normal operation
Front Position: Connection to liquid or suction line closed
Middle Position: All ports open for evacuation, charge and manometer reading
3. Evaporator Unit
The WM25-85SFCD evaporator units shall be installed for ceiling mount
with air supply on both sides and air return on the bottom.
Supply and return air flow from the evaporator unit shall be unobstructed
for at least 1 foot.