Dil ID: 12
Dil Adı: portugal
Dil Kodu: pt3tayfun Produtos da Marca Traulsen
Dünyanın En Büyük
Elektronik Bilgi Kütüphanesi



10
Resetting The Control
Refers To Older Control Versions Only
If memory reaches capacity during a chill cycle there is potential that some printout data could
be incorrect (date & time). This will reset on it’s own, however to do so manually...
FACTORY SETTINGS
VERSION 2.0
S/N:T00000A00
RESET NEXT
STEP 6
Serial number will be
displayed. Press NEXT.
STEP 5
FACTORY SETTINGS
menu. Press RESET.
STEP 10
Press NEXT.
DEFROST TIME (40)
DEFR. TEMP (50)
°F
DEFR. INTVL (3) HR
BACK NEXT
STEP 9
Press NEXT.
STEP 13
Press YES.
STEP 11
Press ENTER.
(do not change code)
SELECT SUPERVISOR:
PRESET SUPERVISOR
PASSWORD (PIN): 00
CANCEL ENTER
BLASTING DIFF (4)°F
HOLDING DIFF (3)
°F
ANTI-SHORT(1)
BACK NEXT
ENTER SECURITY CODE
FOR NEXT SETTINGS:
(000000)
EXIT ENTER
FACTORY SETTINGS
DO YOU WISH TO SAVE
THESE NEW SETTINGS
NO YES
STEP 1
Main Menu display press MORE
STEP 2
Press SETUP.
STEP 3
Enter PASSWORD/PIN 85.
SELECT SUPERVISOR:
TIM SMITH
PASSWORD (PIN): 85
CANCEL ENTER
DISPLAY WILL SHOW
SELECT SUPERVISOR screen
MAIN MENU AIR 35°F
BY TEMP BY PROD
BY TIME
08:05:01 MORE
MAIN MENU 08:06:01
HOLD PROD PRINT
DEFROST SETUP
BACK
STEP 4
Press the top left, top
right, and bottom right buttons
at the same time.
FACTORY SETTINGS
VERSION 2.0
S/N:T00000A00
RESET NEXT
LABEL PRINTER (NO)
RESET NEXT
LABEL PRINTER(YES)
RESET NEXT
STEP 7
Display will ask LABEL
PRINTER (NO), press the UP
arrow to select YES.
STEP 8
Press NEXT.
NEW SOFTWARE
HAS BEEN INSTALLED
SYSTEM PARAMETERS
HAVE BEEN SET!
DISPLAY WILL SHOW
MACH. MODEL (RBC)
MACHINE SIZE(50)
RESET EXIT
STEP 12
MACH. MODEL (RBC)
MACHINE SIZE(50)
RESET EXIT
14. The display will return to the MAIN
MENU. Repeat steps 1-10
15. Press EXIT.
16. Press YES.
Display will ask MACHINE SIZE. Press RESET,
then using the UP or DOWN arrow change for
your model. For RBC50 = 50, RBC100 = 100,
RBC200 = 200. Press EXIT.