67
6.4. TECHNICAL SPECIFICATION
Dimensions and weight without the boot and strap:
• Diameter: 61 mm [2.4 in]
• Thickness: 28 mm [1.1 in]
• Weight: 68 g [2.4 oz]
Depth Gauge:
• Temperature compensated pressure sensor
• Salt water calibrated, in fresh water the readings are about 3% smaller
(calibrated complying with prEN 13319)
• Maximum depth of operation: 80 m [262 ft] (complying with prEN
13319)
• Accuracy: ± 1% of full scale or better from 0 to 80 m [262 ft] at 20°C
[68°F] (complying with prEN 13319)
• Depth display range: 0 … 100 m [328 ft] (over range up to 150 m [492
ft] in an emergency situation)
• Resolution: 0.1 m from 0 to 100 m [1 ft from 0 to 328 ft]
Temperature display:
• Resolution: 1°C [1.5°F]
• Display range: -9 ... +50°C [-9 ... +122°F]
• Accuracy: ± 2°C [± 3.6°F] within 20 minutes of temperature change
Calendar Clock:
• Accuracy: ± 25 s/month (at 20°C [68°F])
• 12/24 h display
Other displays:
• Dive time: 0 to 999 min, counting starts and stops at 1.2 m [4 ft] depth
• Surface time: 0 to 99 h 59 min
• Dive counter: 0 to 99 for repetitive dives
• No-decompression time: 0 to 199 min (- - after 199)
• Ascent time: 0 to 99 min (- - after 99)
• Ceiling depths: 3.0 to 100 m [10 to 328 ft]