3.1 High temp.life test
Temperature +70 ℃
Duration 200hrs
3.2 Low temp.life test
Temperature -25 ℃
Duration 200hrs
3.3 Temperature cycle test
Cycles 5
3.4 Humidity Test
Temperature +40 ℃
Relative Humidity 90~95%
Duration 200hrs
Tests above should be measured after leaving normal temperature for 2hrs.
3.5 Vibration Test
Vibration Frequency 10~55Hz
Amplitude 1.52mm/min
Direction 3(x.y&z)
Duration 2hrs each cycle(total 6 hrs)
3.6 Drop test
Height 100cm
(Dropped to concrete floor in state of packing.)
Direction 3
3.7 Soldering Heat Shock
Temperature 260 ℃ 5
Duration 3±1 sec
3.8 Terminal Mechanical Strength
Strength 1kg
Duration 1 min
Notice:
All specifications must be satisfied in this condition.
Sensitivity :Allowable deviation within ±3dB from initial sensitivity.