Fire Research Focus model FCA100-S75 lamp head shall be provided. The lamp head mounting arm shall
terminate in 3/4" NPT threads. Wiring shall extend from the lamp head mounting arm bottom.
The lamp head shall have one (1) quartz halogen 750 watt 120 volt bulb. The bulb will draw 6.3 amps and
generate 19,600 lumens. The bulb shall be accessible through the front. The lamp head shall direct 50
percent of the light onto the action area while providing 50 percent to illuminate the working area. The lamp
head angle of elevation shall be adjustable at a pivot in the mounting arm and the position locked with a
round knurled locking knob. The lamp head shall incorporate heat-dissipating fins and be no more than 5"
deep by 3 3/8" high by 10" wide. Lamp head and mounting arm shall be powder coated white. The
floodlight shall be UL listed as a scene light for fire service use.
The light head shall be mounted on a side mount push up telescopic pole. The light pole shall be anodized
aluminum and have a knurled twist lock mechanism to secure the extension pole in position. The extension
pole shall rotate 360 degrees. The outer pole shall be a grooved aluminum extrusion and qualify as an NFPA
compliant handrail. The pole mounting brackets shall have a 3 1/2" offset. Wiring shall extend from the pole
bottom with a 4' retractile cord.
ELECTRIC CORD REEL
One (1) Hannay model ECR1616-17-18 electric rewind cord reel(s) shall be supplied and installed.
The cable reel(s) shall be a 12-volt electric rewind type.
One hundred fifty feet (150') of 10/3 SOOW (yellow) cord shall be installed on one (1) reel(s), complete with
an HS-3 ball stop.
One (1) Akron junction box, model EJB shall be provided. The junction box is to be powder coated safety
yellow and be provided with rubber feet on the bottom of the box.
There shall be four L5-20 twist lock outlets furnished.
There shall be a captive roller system furnished for the cord reel. The roller assembly shall be mounted on
the dunnage side wall. If the body selection requires ladders on beam the right side cord reel is elevated and
the rollers are mounted on the cord reel assembly.
The cord reel shall be equipped with a weather resistant push button switch mounted on the side of the pump
module.
PUMP COMPARTMENT
The pump compartment shall be separate from the hose body and compartments so that each may flex
independently of the other. It shall be a fabricated assembly of stainless steel tubing, angles and channels,
which does not support the fire pump and or running boards. The pump compartment shall be mounted onto
the chassis through rubber biscuits in a four point pattern to allow for a chassis frame twist.
Pump compartment, pump, plumbing and gauge panels shall be removable from the chassis in a single
assembly and shall have an approximate width of 47". The pump compartment shall be a modular design.
A stainless steel framework shall provide the support for the mounting of the pump lower panels, speedlay
hose beds, and pump access doors.