4.3.2. Command List for Remote Device
To change the configuration for a remote device via over-the-air, firstly you have to use a
command “O” at the local device. The following are a procedure for changing configuration of
remote device via over-the-air.
z
Configure a remote device at the local device.
z
Save changes at the local device.
z
Make a connection between the local device and remote device (Automatically).
z
Send changes from the local device to the remote device (Automatically).
z
Apply changes at the remote device and reboot (Automatically).
Item Syntax Description Remarks
1. Connecting
address
AAddr<Enter> Set a connecting address for
remote device.
2. Baud rate BBaud Rate Change the baud rate for the
remote.
3. COM port CCOM Port
This is only valid in mode 2.
4. PIN code EPIN<Enter>
Authentication Off: Type <Enter>
Authentication On: Type up to 11
characters
Paired adapters should
have a same PIN code.
5. Flow control FFlow Control
Set the Flow control for remote.
6. Connection
mode
MMode Set a connection mode for
remote.
7. Friendly name NName<Enter> Set a friendly name up to 11
characters for remote.
8. Parity Bit PParity Set the parity bit. 0: None, 1: Odd 2: Even
9. Stop Bit SStop Set the stop bit. 0: 1 Stop, 1: 2 Stop
10 View V Display configuration
information for remote
11. Exit X Save changes and return to
main menu.
12. Usage ? Print the usage.
Remarks1: To configure a remote device via over-the-air, a local device must be able to make a
connection to the remote device.
Remarks2: You can change a PIN code for the remote and local device as follows:
Change a PIN for remote at the local -> Apply it. -> Change a PIN for local and apply it.
Remarks3: Once you change a connecting address, and connection mode for the remote, the
local device won’t be able to make a connection to the remote device.