Diode Test Test current of 0.3mA maximum, open circuit voltage 1.5V DC
typical
Continuity Check Audible signal will sound if the resistance is less than
approximately 30Ω, test current <0.7mA
Input Impedance 7.5MΩ (VDC and VAC)
Display 4000 count LCD
Overrange indication “OL” is displayed
Polarity Automatic (no indication for positive polarity); Minus (-) sign for
negative polarity.
Measurement Rate 2 times per second, nominal
Auto Power Off Meter automatically shuts down after 15 minutes of inactivity
Low Battery Indication “BAT” is displayed
Batteries Requires two AAA batteries
Fuses mA, µA ranges, 0.5A/250V fast blow
10A range, 10A/250V fast blow
Operating Temperature 32
o
F to 122
o
F (0
o
C to 50
o
C)
Storage Temperature -4
o
F to 140
o
F (-20
o
C to 60
o
C)
Relative Humidity <70% operating, <80% storage
Operating Altitude 7000ft (2000 meters) maximum.
Weight 9.17 oz. (260g).
Size 4.78” x 2.38” x 1.57” (121.5mm x 60.6mm x 40mm)
Safety For indoor use and in accordance with Overvoltage Category
II, Pollution Degree 2. Category II includes local level,
appliance, portable equipment, etc., with transient
overvoltages less than Overvoltage Category III.
Meter Description
1. LCD Display
2. Function switch
3. Function key
4. Range key
5. Temperature jack
6. COM jack
7. 10A jack
8. Positive jack
9. Relative key
10. Data Hold key
Note: Tilt stand, fuse and battery compartment are on rear of unit.